Product introduction: Content Hide 1. Introduction and Application of Gate Opening Meter WTM-AS: 2. The micro-special gate opening instrument WTM-AS is suitable for...
Online consultationModel:WTM-AS
The gate measurement and control system is the core equipment used in water conservancy projects to monitor and control the operating status of gates. It collects data such as water level, flow rate and gate opening degree in real time through automation technology, helping managers achieve precise dispatching and ensuring the safe and efficient operation of water conservancy facilities.
In scenarios such as water conservancy hubs, reservoirs, and river management, gate control directly affects functions such as flood control and drainage, as well as irrigation and water supply. For instance, after a large reservoir adopted the micro-special gate measurement and control system, the management personnel could complete the water level adjustment through remote operation, avoiding the time-consuming and risky manual on-site operation, and at the same time reducing the waste of water resources caused by operational errors.
It is mainly used for: automatic measurement and control instruments for measuring, displaying and controlling the lifting capacity and opening degree (height) of hoists, gantry cranes, hoists and other lifting equipment.
The following accessories are based on the application in the hoist shown in the above picture. The safety configurations of different lifting equipment are not the same.
Height encoderAn encoder is a device that encodes signals or data and converts them into a form suitable for communication, transmission and storage. The opening degree instrument uses the height signal obtained by the encoder to receive, sample, analyze, process, identify, display and control.
Weight sensorThe selection of the weight sensor is determined by the actual lifting structure of the crane. For specific details, please consult the customer service. Commonly used weight sensors include PY side pressure weight sensor, ZX pin weight sensor, BH plate ring weight sensor, SHL three-pulley weight sensor, QCX bearing housing weight sensor, etc.
Travel limiterAn encoder is a device that encodes signals or data and converts them into a form suitable for communication, transmission and storage. The opening degree instrument uses the height signal obtained by the encoder to receive, sample, analyze, process, identify, display and control. (This configuration is optional.
Data acquisition unitEquipped with high-precision sensors, it can monitor parameters such as the position, height and weight of the gate in real time.
Control execution unitThe precise control of the opening and closing of the gate is achieved through motor drive or hydraulic device.
Human-computer interaction terminalDigital display, intuitive interface for weight, height and alarm information.
a. Monitoring accuracy
The micro and special gate opening meter adopts high-precision sensors to ensure the accuracy of data collection:
Wide measurement rangeThe gate opening is 0-99.99 meters, with a display accuracy of 0.01 meters (1 centimeter), ensuring that even the slightest changes can be accurately captured.
Weight monitoringSupports weight measurement ranging from 0T to 999.9T and is suitable for water conservancy facilities of different scales.
The signal output is flexible.It can be configured with 4-20mA standard analog output and RS485 communication to meet various industrial control requirements.
Strong scalabilityIt can be expanded to a maximum of 8 control signal outputs and is suitable for multi-point monitoring in complex water conservancy projects.
This system has been applied in hydropower stations and gate projects in multiple river basins. User feedback data is stable and reliable, and there is no deviation in long-term operation.
b. Ease of operation
The micro-special gate opening instrument adopts a self-developed single-chip microcomputer control system, which is simple to operate and highly adaptable.
Intelligent settingThe limit control point of the gate opening can be flexibly set according to the actual needs on site to avoid misoperation.
Embedded installationIt adopts a compact design and can be easily embedded in the electrical control cabinet of a hydropower station, saving space and being easy to install.
Intuitive operationIt is equipped with a clear operation interface, and the parameter adjustment is simple. You can get started without complex training.
Whether it is a new water conservancy project or an upgrade of old equipment, this system can be quickly adapted and improve management efficiency.
c. Operational stability
The micro-special gate opening meter has been verified by the market for many years and has undergone multiple technological iterations to ensure long-term stable operation.
Strict inspectionBefore leaving the factory, each piece of equipment undergoes multiple layers of instrument testing and manual quality inspection to ensure that it meets high standards.
Anti-interference designIt adopts a metal shell, effectively shielding electromagnetic interference and is suitable for complex industrial environments.
Power-off protectionIt is equipped with jitter delay, power-off memory and power failure protection functions, and can still resume operation after an unexpected power failure.
"Extra-long lifespan"The circuit design is optimized, and key components are made of industrial-grade materials. The normal service life can reach more than ten years.
This system has been applied in many large-scale water conservancy projects, such as the flood control project in the Yangtze River Basin and the South-to-North Water Diversion Project, etc. It operates stably with an extremely low failure rate.
Core performance indicators:
Display system: Dual digital tube display screens
Measurement accuracy: ±0.1% range ±1cm
Height measurement: 0-99.99m
Systematic error: ≤5%(F.S.)
Temperature range: -20℃ to +60℃
Humidity range: 90%RH(25℃) No condensation
Protection grade: IP54
The power supply requirement is AC220V±15%
Power consumption: 60db
Measuring range: Weight: 0-999.9 tons
Control output: ≤7 channels
Output mode: Switch quantity /RS485/4-20mA
Installation method: Wall-mounted/bracket
The appearance and dimensions of the gate opening meter WTM-AS
The overall length is 170mm, the width is 97mm, and the thickness is 107mm
The micro and special gate measurement and control system, with intelligence and high reliability at its core, helps water conservancy units achieve a management upgrade from "manual experience" to "data-driven". At present, this product has been successfully applied in the South-to-North Water Diversion Project and the Yangtze River Basin Project, and has served more than 500 customers in total. In the future, Weite will continue to optimize product performance and provide solid technical support for the modernization of water conservancy construction.