{"id":6516,"date":"2025-05-22T09:37:21","date_gmt":"2025-05-22T01:37:21","guid":{"rendered":"https:\/\/www.wtauserver.com\/?p=6516"},"modified":"2025-06-05T15:36:50","modified_gmt":"2025-06-05T07:36:50","slug":"dam-crest-gantry-crane-safety-system","status":"publish","type":"post","link":"https:\/\/www.wtauserver.com\/en\/dam-crest-gantry-crane-safety-system\/","title":{"rendered":"Crest Gate Crane Safety Monitoring System"},"content":{"rendered":"<p><video controls=\"controls\" width=\"521\" height=\"521\"><source src=\"https:\/\/b2b-video.cdn.bcebos.com\/723823cc0aa6d18e5949125d6d437455_transcode.mp4\" type=\"video\/mp4\" \/><\/video><\/p>\n<h2>1. Brief Introduction &amp; Applications<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-6528\" src=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/H0e7a2dafb3d84693bae47d44d605ed67N.jpg_720x720q50-300x300.jpg\" alt=\"top-of-dam gate machine\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/H0e7a2dafb3d84693bae47d44d605ed67N.jpg_720x720q50-300x300.jpg 300w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/H0e7a2dafb3d84693bae47d44d605ed67N.jpg_720x720q50-150x150.jpg 150w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/H0e7a2dafb3d84693bae47d44d605ed67N.jpg_720x720q50.jpg 720w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><br \/>\nModel number: WTM<\/h2>\n<p class=\"ds-markdown-paragraph\"><strong>Crest Gate Crane Safety Monitoring System<\/strong>(Also known as the black box for intelligent monitoring of underwater operations) is specially designed for the safe operation and maintenance of water conservancy projects.<strong>Dynamic data + underwater video dual-channel monitoring<\/strong>, To ensure that the gate lifting and discharging is accurate and controllable. The system is based on<strong>\u226410 milliseconds sampling period<\/strong>Collect key parameters such as the alignment status of the grab beam, the depth of the pin, and the hydraulic pressure in real time, and automatically lock the lifting command when the pin recognition accuracy rate is less than 99%, and encrypt and store the whole process data in an industrial-grade FLASH chip. FLASH chip.<\/p>\n<p class=\"ds-markdown-paragraph\">The system is specially developed by Weite for hydropower station\/dam gate maintenance scenarios.<strong>Highly reliable monitoring equipment<\/strong>, with<strong>Underwater corrosion resistance, anti-turbulence interference, anti-siltation<\/strong>Enhanced protection characteristics.<\/p>\n<p>&nbsp;<\/p>\n<h2>2. Basis for product development\uff1a<\/h2>\n<p>GB12602-1990 &#034;Safety Technical Specifications for Overload Protection Devices for Lifting Machinery&#034;<br \/>\nGB6067.1 &#034;Safety Regulations for Lifting Machinery&#034;<br \/>\nGB\/T 28264-2017 &#034;Safety Monitoring and Management System for Lifting Machinery&#034;<br \/>\nGB\/T 20776 &#034;Classification of Lifting Machinery&#034;<br \/>\nGB11632-1989 &#034;Technical Conditions for Pressure-resistant Structural Materials for Submersibles and Underwater Installations&#034;<\/p>\n<p>&nbsp;<\/p>\n<h2>3. Five pain points in the safety management of water and electricity gate machines\uff1a<\/h2>\n<p><strong>The electronic control system is mixed and difficult to be compatible<\/strong><br \/>\n\u25b6 Old logic circuits, PLC, and COMS systems coexist, and the cost of adapting monitoring equipment has soared.<\/p>\n<p><strong>No monitoring at all for underwater operations<\/strong><br \/>\n\u25b6The alignment of the piercing pin depends purely on manual judgment, and there is a risk of falling when the gate is hoisted.<\/p>\n<p><strong>Serious shortage of historical data storage<\/strong><br \/>\n\u25b6 The storage capacity of traditional systems is low, and there is no basis for fault traceability.<\/p>\n<p><strong>Operation instruction collection failed<\/strong><br \/>\n\u25b6 Mixed circuits cause key instructions (such as lifting\/turning) to not be accurately captured<\/p>\n<p><strong>Chain outbreak of maintenance hazards<\/strong><br \/>\n\u25b6Equipment blind spot + missing data \u2192 sudden shutdown \u2192 Maintenance cycle doubled<\/p>\n<p>&nbsp;<\/p>\n<h2>4. Solutions for the safety management of water and electricity gate machines\uff1a<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-6685\" src=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/de5821cadd67845505b1839e7ab5bb5d.webp\" alt=\"Safety management plan for dam top door machine\" width=\"750\" height=\"513\" srcset=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/de5821cadd67845505b1839e7ab5bb5d.webp 750w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/de5821cadd67845505b1839e7ab5bb5d-300x205.webp 300w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/p>\n<p><strong>Adaptation of the original system with zero changes<\/strong><br \/>\n\u25b6 Pass<strong>PLC communication + switch command dual-channel acquisition<\/strong>, Get the operation command\/limit status\/brake signal<br \/>\n\u25b6 Reuse the original equipment sensors, and only install key detection modules incrementally<\/p>\n<p><strong>Global video surveillance coverage<\/strong><br \/>\n\u25b6 Added three high-definition video streams\uff1a<br \/>\n-Anti-collision monitoring for large vehicle travel areas<br \/>\n- Tracking of the trolley hook trajectory<br \/>\n- Real-time footage of underwater pin threading operation (with voice intercom)<\/p>\n<p><strong>Precise control of underwater operations<\/strong><br \/>\n\u25b6 Deploy an anti-turbulent hydraulic sensor array to monitor the alignment deviation of the grab beam (\u00b12mm) in real time<br \/>\n\u25b6 Infrared laser assisted positioning, ** Pin in place recognition rate\u226599.9%**<\/p>\n<p><strong>National standard compliance guarantee<\/strong><br \/>\n\u25b6 All functions meet**GB\/T28264-2017** standard certification<br \/>\n\u25b6 Reserve an open API interface to support seamless compatibility with future national standard upgrades<\/p>\n<p><strong>Intelligent diagnosis and pre-maintenance<\/strong><br \/>\n\u25b6 Build a digital twin of the operating state of the mechanism<br \/>\n\u25b6 Predict the risk of brake failure\/wire rope wear based on big data<\/p>\n<p>&nbsp;<\/p>\n<h2>5. Related configuration\uff1a<\/h2>\n<p>Taking the figure in Section 4 as an example, it basically covers most of the gate machines of hydropower stations. Of course, different environments and applications are different, and professional customization is supported.<\/p>\n<p>Sensor terminal: skew sensor, displacement limit, wind speed sensor, ranging sensor, brake limit, pin position sensor, over-discharge sensor, pin sensor, height sensor\u3001<br \/>\nDisplay terminal: video monitor, 10.4-hour color display<br \/>\nTransmission terminal: I\/O module<\/p>\n<p>&nbsp;<\/p>\n<h2>6. Transformation case\uff1a<\/h2>\n<p>Smart Door machine Renovation Project of Guheyan Hydropower Station\uff1a<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-6686\" src=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/1-160H2095425452.webp\" alt=\"Guheyan Hydropower Station Gate Machine Renovation Project\" width=\"750\" height=\"513\" srcset=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/1-160H2095425452.webp 750w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/05\/1-160H2095425452-300x205.webp 300w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>1. Introduction and Application: Model: WTM Dam Top Gantry Crane Safety Monitoring System (also known as Underwater Operation Intelligent Monitoring Black Box) is specially designed for the safe operation and maintenance of water conservancy projects. It is compatible with [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[123],"tags":[],"class_list":["post-6516","post","type-post","status-publish","format-standard","hentry","category-crane-safety-monitoring-system"],"_links":{"self":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/6516","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/comments?post=6516"}],"version-history":[{"count":0,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/6516\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/media?parent=6516"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/categories?post=6516"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/tags?post=6516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}