{"id":7385,"date":"2025-07-24T12:00:54","date_gmt":"2025-07-24T04:00:54","guid":{"rendered":"https:\/\/www.wtauserver.com\/?p=7385"},"modified":"2025-07-24T12:00:54","modified_gmt":"2025-07-24T04:00:54","slug":"micromagnetic-grid-displacement-sensor-wtcwy-series","status":"publish","type":"post","link":"https:\/\/www.wtauserver.com\/en\/micromagnetic-grid-displacement-sensor-wtcwy-series\/","title":{"rendered":"Micro-magnetic grid displacement sensor WTCWY series"},"content":{"rendered":"<h3><strong>1. Product Introduction<\/strong><\/h3>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-7386 aligncenter\" src=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/3-7.webp\" alt=\"Micro-magnetic grid displacement sensor WTCWY series\" width=\"590\" height=\"443\" srcset=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/3-7.webp 590w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/3-7-300x225.webp 300w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/3-7-16x12.webp 16w\" sizes=\"auto, (max-width: 590px) 100vw, 590px\" \/>\u200b<\/h3>\n<p>\u200b<strong>WTCWY series micro-magnetic grating displacement sensor<\/strong>\u200b<br \/>\n\"Adopt<strong>Non-contact measurement technology with static magnetic grid<\/strong>High-precision displacement detection equipment. It is achieved through the interaction between the magnetic grid source built into the stainless steel pipe (round pipe\/square pipe) and the external reader<strong>Accuracy: \u00b10.1mm within a range of 0 to 10 meters<\/strong>Position feedback. The core advantage lies in<strong>IP69 level protection<\/strong>with<strong>Mechanical shock resistance design<\/strong>It is specially developed for harsh working conditions such as heavy machinery and hydraulic gates.<\/p>\n<h3>\u200b<strong>2. Main functions<\/strong>\u200b<\/h3>\n<p>\u200b<strong>Precision displacement perception and industrial-grade protection<\/strong>\u200b<\/p>\n<ul>\n<li>\u200b<strong>Nanoscale magnetic grid analysis<\/strong>\u200b<br \/>\nPeriodic magnetic array of static magnetic grid source (0.1mm spacing)<br \/>\nThe resolution reaches 0.1mm (maintaining accuracy even at a range of 10m)<\/li>\n<li>\u200b<strong>Multi-signal output compatibility<\/strong>\u200b<br \/>\nFive types of interfaces: RS485, SSI, analog, voltage, and CANbus<\/li>\n<li>\u200b<strong>Extreme working condition protection<\/strong>\u200b<br \/>\n\u2192 IP67\u3001IP68\u3001IP69<\/li>\n<li>\u200b<strong>Anti-interference enhancement<\/strong>\u200b<br \/>\nThe pipe body absorbs mechanical vibrations<\/li>\n<\/ul>\n<h3>\u200b<strong>3. Scope of application<\/strong>\u200b<\/h3>\n<p>\u200b<strong>Heavy industry and harsh outdoor scenarios<\/strong>\u200b<\/p>\n<div class=\"hyc-common-markdown__table-wrapper\" data-has-scroll=\"false\">\n<table>\n<thead>\n<tr>\n<th>\u200b<strong>Application field<\/strong>\u200b<\/th>\n<th>\u200b<strong>Typical scenarios<\/strong>\u200b<\/th>\n<th>\u200b<strong>Core value<\/strong>\u200b<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Water conservancy and hydropower<\/td>\n<td>Gate opening degree monitoring<\/td>\n<td>Resistant to water pressure corrosion, the accuracy is not affected by water mist<\/td>\n<\/tr>\n<tr>\n<td>Construction machinery<\/td>\n<td>Stroke positioning of hydraulic cylinders<\/td>\n<td>Resistant to oil stains and vibration interference<\/td>\n<\/tr>\n<tr>\n<td>rail traffic<\/td>\n<td>Monitoring of track expansion joints<\/td>\n<td>IP69 protection resistant to high-pressure cleaning<\/td>\n<\/tr>\n<tr>\n<td>Automated production line<\/td>\n<td>Repeat positioning of the mechanical arm<\/td>\n<td>The SSI interface supports closed-loop control<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>\u200b<strong>4. Model description<\/strong><\/h3>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-7387 aligncenter\" src=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/1-18.webp\" alt=\"Two models\" width=\"554\" height=\"471\" srcset=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/1-18.webp 554w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/1-18-300x255.webp 300w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/1-18-14x12.webp 14w\" sizes=\"auto, (max-width: 554px) 100vw, 554px\" \/>\u200b<\/h3>\n<p>\u200b<strong>Two major structural types, fully covering the range of 0 to 10 meters<\/strong>\u200b<\/p>\n<h4>\u200b<strong>\u2460 Circular tube structure sensor (WTCWY-DC2<\/strong>\u200b<\/h4>\n<ul>\n<li>\u200b<strong>Main material<\/strong>Seamless stainless steel round pipe<\/li>\n<li>\u200b<strong>Range classification<\/strong>\u200b\uff1a<\/li>\n<li>\n<blockquote><p>Short range: 0-2m (accuracy \u00b10.05mm)<br \/>\nLong range: 2-10m (accuracy \u00b10.1mm)<\/p><\/blockquote>\n<\/li>\n<li>\u200b<strong>Protective characteristics<\/strong>\u200b\uff1aIP67<\/li>\n<\/ul>\n<h4>\u200b<strong>\u2461 Square tube structure sensor (WTCWY-DC3<\/strong>\u200b<\/h4>\n<ul>\n<li>\u200b<strong>Main material<\/strong>Stainless steel square tubes<\/li>\n<li>\u200b<strong>Torsional strengthening<\/strong>Square tube structure enhances lateral load capacity (applicable to vibration scenarios)<\/li>\n<li>\u200b<strong>Installation advantages<\/strong>Flat bolt fixation (compared with round pipes, which need to be clamped tightly)<\/li>\n<\/ul>\n<h3>\u200b<strong>5. Installation illustration<\/strong><\/h3>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-7388 aligncenter\" src=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/2-18.webp\" alt=\"Installation illustration\" width=\"554\" height=\"416\" srcset=\"https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/2-18.webp 554w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/2-18-300x225.webp 300w, https:\/\/www.wtauserver.com\/wp-content\/uploads\/2025\/07\/2-18-16x12.webp 16w\" sizes=\"auto, (max-width: 554px) 100vw, 554px\" \/>\u200b<\/h3>\n<p>\u200b<strong>Code for Installation of Concrete Bases in Water Conservancy Projects<\/strong>\u200b<\/p>\n<blockquote><p>\u200b<strong>Installation location<\/strong>The sensor is parallel to the gate guide rail<br \/>\n\u200b<strong>Component Description<\/strong>\u200b\uff1a<\/p><\/blockquote>\n<ul>\n<li>\u200b<strong>A. Sensor body<\/strong>(Blue square tube WTCWY-DC3) :<br \/>\nIt is fixed to the concrete wall through an L-shaped bracket (grayish-white)<\/li>\n<li>\u200b<strong>B. Reading head slider<\/strong>(Silver module on the right side of the tube body)<br \/>\nThe magnetic grid signal pick-up point is connected to the gate moving mechanism<\/li>\n<li>\u200b<strong>C. Shock-absorbing base<\/strong>(Rubber pad at the bottom of the bracket)<br \/>\nAbsorb the vibration of concrete walls<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>1. Product Introduction: The WTCWY series micro-magnetic grating displacement sensor adopts the non-contact measurement technology of static magnetic grating for high-precision displacement detection [...]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[127,132],"tags":[],"class_list":["post-7385","post","type-post","status-publish","format-standard","hentry","category-gate-monitoring-and-control-system","category-water-resources-hydropower"],"_links":{"self":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/7385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/comments?post=7385"}],"version-history":[{"count":2,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/7385\/revisions"}],"predecessor-version":[{"id":7390,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/7385\/revisions\/7390"}],"wp:attachment":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/media?parent=7385"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/categories?post=7385"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/tags?post=7385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}