{"id":8728,"date":"2026-11-20T14:36:05","date_gmt":"2026-11-20T06:36:05","guid":{"rendered":"https:\/\/www.wtauserver.com\/?p=8728"},"modified":"2026-11-20T14:36:05","modified_gmt":"2026-11-20T06:36:05","slug":"how-to-choose-instruments-for-lifting-equipment","status":"publish","type":"post","link":"https:\/\/www.wtauserver.com\/en\/how-to-choose-instruments-for-lifting-equipment\/","title":{"rendered":"How to choose the instrument of lifting equipment? One table + five-step method, you will see it after reading it"},"content":{"rendered":"<p>Wtau-technology  Dry goods Classroom\uff5cCompiled from Professional Knowledge Training Materials Application<\/p>\n<p>Let's start with the conclusion: the selection actually only captures two things\u2014\u2014<strong>See the structure of the crane clearly<\/strong>\uff0c<strong>Figure out how to install the sensor<\/strong>\u3002 The rest is a set of processes.<\/p>\n<h2>1, get to know the instrument family first: who is in charge of what<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.wtauserver.com\/en\/product-center\/related-products\/overload-limiter\/\"><strong>Lifting capacity limiter<\/strong><\/a>\uff1a\u53ea\u7ba1&#8221;\u91cd\u91cf&#8221;\uff0c\u8d85\u91cd\u5c31\u62a5\u8b66\u3001\u63a7\u5236\u3002\u7528\u4e8e\u6865\u673a\u3001\u9f99\u95e8\u540a\u3001\u67b6\u6865\u673a\u3002<\/li>\n<\/ul>\n<ul>\n<li><a href=\"https:\/\/www.wtauserver.com\/en\/product-center\/related-products\/load-moment-limiter\/\"><strong>Load Moment Limiters<\/strong><\/a>\uff1a\u7ba1&#8221;\u89d2\u5ea6\uff08\u5e45\u5ea6\uff09+ \u91cd\u91cf&#8221;\u3002\u56e0\u4e3a\u81c2\u67b6\u4e00\u53d8\u89d2\u5ea6\uff0c\u80fd\u540a\u7684\u91cd\u91cf\u4e5f\u8ddf\u7740\u53d8\uff08\u8fd9\u5c31\u662f&#8221;\u529b\u77e9&#8221;\u5173\u7cfb\uff09\u3002\u7528\u4e8e\u95e8\u5ea7\u673a\u3001\u6c7d\u8f66\u540a\u3001\u5c65\u5e26\u540a\u3001\u5854\u673a\u7b49\u3002<\/li>\n<\/ul>\n<ul>\n<li><a href=\"https:\/\/www.wtauserver.com\/en\/gate-opening-monitor\/\"><strong>Integrated monitor<\/strong><\/a>\uff1a\u540c\u65f6\u7ba1&#8221;\u9ad8\u5ea6 + \u91cd\u91cf&#8221;\uff0c\u5e38\u89c1\u4e8e\u6c34\u7535\u7ad9\u7684\u95f8\u95e8\u542f\u95ed\u673a\u3002<\/li>\n<\/ul>\n<ul>\n<li><strong><a href=\"https:\/\/www.wtauserver.com\/en\/wtg-as\/\">Altimeter<\/a> \/ <a href=\"https:\/\/www.wtauserver.com\/en\/wtf-b510-anemometer-and-wind-direction-sensor\/\">Anemometer<\/a> \/ <a href=\"https:\/\/www.wtauserver.com\/en\/wfx-series-wind-direction-sensor\/\">Anemometer<\/a> \/ Water level meter \/ <a href=\"https:\/\/www.wtauserver.com\/en\/wtau-qgx-lift-height-limiter\/\">Speed limiter<\/a> \/ <a href=\"https:\/\/www.wtauserver.com\/en\/grab-beam-through-pin-seating-sensors\/\">Pin placement instrument<\/a><\/strong>: Each tube has a special signal as a supplement to the main instrument.<\/li>\n<\/ul>\n<blockquote><p>Analysis: The lifting weight limiter only measures the weight; the torque limiter measures the angle + weight; the comprehensive monitor measures the height + weight.<\/p><\/blockquote>\n<h2>\u4e8c\u3001\u9009\u578b\u6838\u5fc3\uff1a\u4e07\u80fd&#8221;\u4e94\u6b65\u6cd5&#8221;<\/h2>\n<ol>\n<li><strong>Set type<\/strong>: Look at the structure-is there any change in the angle\/amplitude of the boom? Do you want to measure the height? Decide whether to use a lifting weight limiter, torque limiter or a comprehensive monitor.<\/li>\n<\/ol>\n<ol>\n<li><strong>Stereotype number<\/strong>: Look at the mechanism-several lifting mechanisms, several hooks, several sensors, and several control outputs.<\/li>\n<\/ol>\n<ol>\n<li><strong>Fixed sensor<\/strong>: Look at the mechanical structure and installation method, from <a href=\"https:\/\/www.wtauserver.com\/en\/py-side-pressure-type-weight-sensor\/\">PY<\/a> Choose from \/ BH \/ QCX \/ZX \/ JZ \/ SHL \/ LF.<\/li>\n<\/ol>\n<ol>\n<li><strong>Quantitative process<\/strong>: First count the force of a single wire rope, and then add a little margin. formula\uff1a<strong>Force of a single wire rope = rated lifting weight \u00f7 wire rope magnification<\/strong>(Shaft pins are counted separately).<\/li>\n<\/ol>\n<ol>\n<li><strong>Fixed line length<\/strong>: Handle operation asks about the length of the handle line; cab operation allows customers to provide the length of the line from the sensor to the instrument.<\/li>\n<\/ol>\n<blockquote><p>\u26a0The two most easily overlooked points: \u2460 As long as the boom can change the angle\/amplitude, you must install a lengthimeter (or lengthimeter) and ask the customer for it.<strong>Working curve table<\/strong>; \u2461The most difficult to determine is often<strong>Sensor model<\/strong>, First figure out how to install the sensor, and then judge it based on the structure of the crane.<\/p><\/blockquote>\n<h2>3, one-key comparison table of 11 types of cranes<\/h2>\n<table data-sc-row-header=\"true\">\n<tbody>\n<tr>\n<td>Crane type<\/td>\n<td>Instrument type<\/td>\n<td>Commonly used models<\/td>\n<td>Weight sensor<\/td>\n<td>Key reminder<\/td>\n<\/tr>\n<tr>\n<td>Electric hoist<\/td>\n<td>Lifting weight<\/td>\n<td>Handle WTZ-A(50); cab WTZ-A above 100<\/td>\n<td>With fixed rope PY; without fixed rope ZX<\/td>\n<td>PY wants to ask about the diameter of the wire rope<\/td>\n<\/tr>\n<tr>\n<td>Bridge crane<\/td>\n<td>Lifting weight<\/td>\n<td>Single hook WTZ-A (100); main + secondary hook WTZ-A (200)<\/td>\n<td>PY \/ BH \/ QCX \/ ZX<\/td>\n<td>The difficulty lies in the selection of sensors<\/td>\n<\/tr>\n<tr>\n<td>Gantry crane<\/td>\n<td>Lifting weight<\/td>\n<td>Single hook WTZ-A (100); main + secondary hook WTZ-A (200)<\/td>\n<td>PY \/ BH \/ QCX \/ ZX<\/td>\n<td>Anemometer and altimeter can be added<\/td>\n<\/tr>\n<tr>\n<td>Bridge building machine<\/td>\n<td>Lifting weight<\/td>\n<td>WTZ-A(200)\/(230)\/(240)\/(300)<\/td>\n<td>PY \/ BH \/ QCX \/ ZX<\/td>\n<td>The question list point shows the total weight and the number of hoists\/hooks.<\/td>\n<\/tr>\n<tr>\n<td>Optical Signal Reflection and Acquisition:<\/td>\n<td>torque<\/td>\n<td>2 mechanism WTL-A (200) or more; &gt;4 sensor WTL-A (300) or more<\/td>\n<td>PY \/ BH \/ JZ \/ ZX<\/td>\n<td>Compulsory degree meter + curve table<\/td>\n<\/tr>\n<tr>\n<td>Quadruple pole crane<\/td>\n<td>torque<\/td>\n<td>WTL-A (200) and above<\/td>\n<td>JZ \/ ZX \/ SHL<\/td>\n<td>Two working conditions of grab\/hook; the range is based on the maximum lifting weight +magnification<\/td>\n<\/tr>\n<tr>\n<td>Car crane<\/td>\n<td>torque<\/td>\n<td>WTL-A (200) or more (weight + angle + arm length)<\/td>\n<td>SHL<\/td>\n<td>Pay attention to the angle\/length gauge, left-mounted and right-mounted direction+curve table<\/td>\n<\/tr>\n<tr>\n<td>Crawler crane<\/td>\n<td>torque<\/td>\n<td>WTL-A (200) and above<\/td>\n<td>SHL \/ BH \/ PY (mainly SHL)<\/td>\n<td>Compulsory degree meter + curve table<\/td>\n<\/tr>\n<tr>\n<td>Tower crane<\/td>\n<td>torque<\/td>\n<td>All torque limiters are available<\/td>\n<td>ZX \/ SHL \/ PY<\/td>\n<td>First divide the trolley luffing type \/ boom type and then set the luffing method<\/td>\n<\/tr>\n<tr>\n<td>Dam top door machine<\/td>\n<td>Synthesis\/threading<\/td>\n<td>WTM full range; WTM-E for piercing<\/td>\n<td>LF \/ QCX \/ ZX<\/td>\n<td>Install encoder + weight sensor; ask for communication and control signals<\/td>\n<\/tr>\n<tr>\n<td>Gate opener<\/td>\n<td>comprehensive<\/td>\n<td>WTM full range<\/td>\n<td>LF \/ QCX \/ ZX<\/td>\n<td>Install encoder + weight sensor; ask for communication and control signals<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: The A (100), A (200), and A (300) in the model mainly correspond to the number of sensors\/mechanisms and the number of display channels, and ultimately the actual needs of customers and the mechanical structure shall prevail.<\/p>\n<h2>4. Before placing an order, remember to ask customers these questions<\/h2>\n<ul>\n<li>Rated lifting weight, wire rope magnification, wire rope diameter (required for PY sensor)\uff1b<\/li>\n<\/ul>\n<ul>\n<li>Handle operation or cab operation? Is there a fixed end (fixed rope) of the wire rope?<\/li>\n<\/ul>\n<ul>\n<li>There are several lifting mechanisms, several hooks, and several sensors. Do you need to display each lifting point independently?\uff1b<\/li>\n<\/ul>\n<ul>\n<li>Is the boom luffing\/retracting? Do you need to measure the angle, arm length or amplitude?<\/li>\n<\/ul>\n<ul>\n<li><strong>Working curve table<\/strong>(Required for torque type); installation direction of angle\/length gauge\uff1b<\/li>\n<\/ul>\n<ul>\n<li>The length of the signal line from the sensor to the instrument; whether there are communication requirements and how many control signals are required\uff1b<\/li>\n<\/ul>\n<ul>\n<li>Do you still need additional instruments such as anemometer, altimeter, and water level meter?<\/li>\n<\/ul>\n<h2>5, write at the end<\/h2>\n<p>\u5206\u6790\u4e00\u53f0\u540a\u8f66\uff0c\u672c\u8d28\u5c31\u662f&#8221;\u770b\u7ed3\u6784\u3001\u770b\u5b89\u88c5\u3001\u5957\u4e94\u6b65&#8221;\u3002\u7ed3\u6784\u51b3\u5b9a\u4e86\u4eea\u8868\u7c7b\u578b\uff0c\u673a\u6784\u6570\u91cf\u51b3\u5b9a\u4e86\u578b\u53f7\uff0c\u5b89\u88c5\u65b9\u5f0f\u51b3\u5b9a\u4e86\u4f20\u611f\u5668\uff0c\u989d\u5b9a\u91cd\u91cf\u9664\u4ee5\u500d\u7387\u51b3\u5b9a\u4e86\u91cf\u7a0b\u3002\u628a\u516c\u53f8\u7684\u4ea7\u54c1\u5403\u900f\uff0c\u5224\u65ad\u81ea\u7136\u53c8\u5feb\u53c8\u51c6\u3002<\/p>\n<blockquote><p>Remember the full text in one sentence: look at the structure setting type, look at the mechanism setting number, look at the installation setting sensor, the rated weight divided by the magnification range, and finally don't forget to ask the cable length\u2014\u2014<strong>If there is a boom, there must be an angle meter and a curve meter.<\/strong><\/p><\/blockquote>\n<hr \/>\n<p><em>This article is compiled from the \"Professional Knowledge Training Materials and Applications\" of Weite Technology Co., Ltd. and is for learning and communication only.<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>\u5fae\u7279\u6280\u672f \u00b7 \u5e72\u8d27\u8bfe\u5802\uff5c\u6574\u7406\u81ea\u300a\u4e13\u4e1a\u77e5\u8bc6\u57f9\u8bad\u6559\u6750 \u00b7 \u5e94\u7528\u7bc7\u300b \u5148\u8bf4\u7ed3\u8bba\uff1a\u9009\u578b\u5176\u5b9e\u53ea\u6293\u4f4f\u4e24\u4ef6\u4e8b\u2014\u2014\u770b\u6e05\u540a\u8f66\u7684\u7ed3 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[97],"tags":[],"class_list":["post-8728","post","type-post","status-publish","format-standard","hentry","category-technical-support"],"_links":{"self":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/8728","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/comments?post=8728"}],"version-history":[{"count":1,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/8728\/revisions"}],"predecessor-version":[{"id":8729,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/posts\/8728\/revisions\/8729"}],"wp:attachment":[{"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/media?parent=8728"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/categories?post=8728"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wtauserver.com\/en\/wp-json\/wp\/v2\/tags?post=8728"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}